Midmark M11 Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Drucken & Scannen Midmark M11 herunter. Midmark M11 Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 44
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Description
Page 6
Components
Overview
Page 8
Controls &
Indicators
Page 9
Calling For
Service
Page 28
Operation
Page 11
Specifications
Page 29
Operator
Maintenance
Page 20
Installation
Page 4
Important
Information
Page 2
Limited
Warranty
Page 29
Installation
& Operation
Manual
M11 UltraClave™
Steam Sterilizer
M11 UltraClave
®
O
N
/S
TA
N
D
B
Y
E
R
R
O
R
S
TO
P
D
O
O
R
AJAR
STAR
T
W
ATER
LO
W
P
AC
K
S
C
O
M
PLETE
LIQ
U
ID
S
D
R
Y
IN
G
P
O
U
C
H
ES
S
TER
ILIZIN
G
U
N
W
R
AP
PE
D
FILLIN
G
P
R
E
S
S
U
R
E
(P
S
I)
T
E
M
P
(
°
F
) \ T
IM
E
(M
IN
: S
E
C
O
N
D
S
)
No Longer in Production:
SERVICE PARTS NO LONGER
AVAILABLE FOR THIS PRODUCT!
Go To Table Of Contents
Style L
Seitenansicht 0
1 2 3 4 5 6 ... 43 44

Inhaltsverzeichnis

Seite 1 - Steam Sterilizer

DescriptionPage 6ComponentsOverviewPage 8Controls &IndicatorsPage 9Calling ForServicePage 28OperationPage 11SpecificationsPage 29OperatorMaintenan

Seite 2 - Go To Table Of Contents

8COMPONENTS OVERVIEWThe illustration below shows the location of the sterilizer’s major components and the chart below provides their descriptive name

Seite 3 - CONTENTS

9CONTROLS & INDICATORSThe following illustrations show the location of the sterilizer’s controls and indi-cators and the chart on the following pa

Seite 4 - Safety Instructions

10Ref. Control Function1 Temperature / Time dis-playalternately indicates cycle temperature and exposure time when a cycle is selected. Dur-ing a cyc

Seite 5

11OPERATION14 START button when pressed, initiates the program cycle that has been selected.15 STOP button when pressed, terminates the program cycle

Seite 6 - INSTALLATION

12Recommended Steam Sterilization Monitoring Pro-gramPhysical monitors (temperature and pressure measuring devices) can be used to help detect failure

Seite 7

132. Open the door and pour distilled or demineralized water into the fill opening (2) until the water level found in the Level Indicator Tube (3) is

Seite 8 - Operational Features

14Guidelines For Loading TraysSterilizer loading is critical to effective sterilization. Protective coverings designed to be used in steam sterilizat

Seite 9 - Safety Features

15Loads Including Dental Handpieces and/or InstrumentsThe maximum M11 load shall be nine handpieces (in the pouch rack) and 75 in-struments. Other co

Seite 10 - COMPONENTS OVERVIEW

16OperationRefer to the following steps for a detailed description of the program operating procedures: WARNINGDo not use this sterilizer in an explos

Seite 11 - CONTROLS & INDICATORS

17hide1.Press the ON / STANDBY button (1).•The Selector / Indicator panel turns on (displays will illuminate).•The Program Indicator lamps (2) flash u

Seite 12 - Return To Table Of Contents

Owner’s Product Identification(information that you will need to provide for servicing - key information is highlighted)Date of Purchase Serial Number

Seite 13 - OPERATION

18• The sterilizer automatically begins processing its sterilization load.• The FILLING lamp (5) illuminates and the chamber automatically fills to th

Seite 14 - EQUIPMENT ALERT

19Standard Cycle ParametersThe following table lists the standard cycle parameters for the four different types of sterilizer loads (follow state and

Seite 15 - Cleaning Instruments

20• M11 Sterilizer Deep Tray 9A225001• Sterilizer Pouch Rack 9A226001• M11 Horizontal Cassette Rack 9A215001• M11 Vertical Cassette Rack 9A215002OPERA

Seite 16 - General Guidelines

21(a) Drain reservoir and fill with clean, distilled water then add one ounce of Speed Clean Sterilizer Cleaner to a cool chamber.(b) Run one 30 minut

Seite 17

22(a) Remove the top inspection cover (1).(b) Select the UNWRAPPED cycle and START the cycle.(c) When the “heat up” portion of the cycle is complete a

Seite 18 - Operation

233. Cleaning Chamber Filter:(a) Before performing this pro-cedure, make sure that the sterilizer has cooled to room temperature.(b) Open the steriliz

Seite 19

24(a)Open sterilizer door. Then, remove dam gasket (1) and door gasket (2) from door(3).(b)Clean the gaskets (1 and 2) with a mild detergent and insp

Seite 20

25Sterilization failure evidence from process monitor (chemical indicator, biological indicator, etc.)sterilization conditions were not present at the

Seite 21 - Standard Cycle Parameters

26Error Code GuideUse the following table to determine the meaning of an error code and assist in correcting minor problems with the sterilizer.steril

Seite 22 - OPERATOR MAINTENANCE

27Error Code 5(excessive pressure)sterilizer overloaded with gauze or linen packs.reload the sterilizer in accordance with Guidelines for Loading Tray

Seite 23

CONTENTSIMPORTANT INFORMATION ... 2Scope and Purp

Seite 24

28Calling For ServiceIf you are having a problem or have a question, refer to the inside front cover of this manual and call your dealer. Make sure t

Seite 25 - Quarterly

29SPECIFICATIONSPhysical Dimensions:Overall Length...559 mm (22 in)Overall Width...457 m

Seite 26 - Troubleshooting Guide

30products the defects of which are reported to Midmark within the applicable warranty period and which, upon examination by Midmark, prove to be defe

Seite 27

31Installing the Printer1. Unplug the power cord from wall outlet.2. Remove top inspection cover (1) from top cover (2).3. Remove two screws (3) and p

Seite 28 - Error Code Guide

326. Plug PCB printer harness (1) into PC board (2).7. Route PCB printer harness (1) through harness clip (3) to prevent harness from contacting hot p

Seite 29

3310.Insert two tabs (A) of right hand side panel (1) into two slots (B) of base (2).11.Raise top edge of right hand side panel (1) into position unde

Seite 30 - Calling For Service

34Operating the PrinterThe paper feed switch on the printer is a rocker type switch. Push the left side (A) of the rocker switch to toggle the printe

Seite 31 - LIMITED WARRANTY

356. While holding the paper (1) in place, press the right side (B) of the switch to the ON / FEED position and hold. The printer will activate and a

Seite 32

36Installing a New Cartridge Ribbon1. Press the left side (A) of the rocker switch to toggle the printer OFF (the lamp will turn off).2. Four small gr

Seite 33 - Installing the Printer

37Removing the Paper RollBefore removing the paper roll, advance the paper about 2.5 cm (1 in.) beyond the paper cutter by pressing down and holding t

Seite 34

2IMPORTANT INFORMATIONScope and Purpose of This ManualThis manual provides complete instructions for the installation, operation, and normal care of t

Seite 35

38The figure below shows an example of a typical printout of a program cycle:Typical Printout of a Program CycleREADYBEGINSET TEMP: 270FTEMPERATURESET

Seite 36 - Inserting the Paper

39NOTES:Return To Table Of Contents

Seite 37 - About the Cartridge Ribbon

40NOTES:Return To Table Of Contents

Seite 38

Return To Table Of Contents

Seite 39 - Printer Tape Description

003-1030-00 Rev. F (3/03)Midmark Corporation60 Vista DriveP.O. Box 286Versailles, Ohio 45380-0286937-526-3662Fax 937-526-5542midmark.comReturn To Tab

Seite 40

3ImportantInformationExplanation of Safety Symbols and NotesTransportation and Storage Conditions• Ambient Temperature Range:... -40°C to +70°C (-40

Seite 41

4INSTALLATIONLocation Requirements For SterilizerAdherence to the following recommendations for location of the sterilizer will contribute to optimum

Seite 42

5Support Surface Depth (C) - Support surface should be approximately 533 mm (21 in) deep. Allow at least 51 mm (2 in) clearance behind the sterilize

Seite 43

6Electrical RequirementsThe electrical rating for the 230 VAC unit is 230 VAC, 50/60 Hz, 10 amps. The electrical rating for the 120 VAC unit is 120 V

Seite 44

7program cycle is complete by sounding five audible “beeps”. The sterilizer may be switched to standby at this time or restarted if additional steril

Kommentare zu diesen Handbüchern